| Ancillary Equipment and Accessories | |
| print this page Hopewell Designs, Inc. | |
| Optional enhancements for new systems and upgrades for existing systems | |
|
|
|
| T20 Linear Positioning System | |
|
The Linear Positioning System (LPS) positions instruments, dosimetry, phantoms, etc. precisely and repeatably. The computer controlled LPS is linked to the exposure calculator so that the operator may specify the exposure by distance or exposure rate, time or exposure. |
Linear Positioning System (installed as an upgrade to an existing irradiator) |
|
|
|
|
|
|
return to top
|
|
| InstCam-BW-A Instrument Camera |
LPS Instrument Platform and Carrier with Rotary and Vertical axes and Instrument Camera (also visible are Jog controls, leveling anchors, and Camera LCD display) |
|
The Instrument Camera allows the operator to remotely monitor an intrument while it is exposed to radiation. A small LCD monitor is provided to facilitate camera setup, and the video signal is brought out to the control panel. An optional interface is available for computer controlled systems to display the video on the computer monitor. |
|
|
|
|
|
|
|
return to top
|
|
| Jigs and Fixtures | |
|
Jigs and fixtures ensure quick, accurate, repeatable positioning of instruments, dosimetry, ion chambers, etc. on the Instrument Platform. |
Sample Ion Chamber and MicroRem Jigs with a Bicron MicroRem instrument |
|
|
|
|
|
|
return to top
|
|
| Calibration Phantoms | |
|
Phantoms may be used to simulate flesh when calibrating dosimetry equipment. |
40 cm x 40 cm x 15 cm Calibration Phantom |
|
|
|
|
|
|
return to top
|
|
| LaserAlign-PB Laser Alignment System | |
|
The Laser Alignment System accurately traces the centerline of the radiation beam. It may be used to align the LPS or to verify that an instrument or dosimeter is positioned exactly in the center of the beam. |
|
|
|
|
|
|
|
return to top
|
|
| Atten-8000X Attenuator Set | |
|
With an attenuator set, one source can function at up to sixteen virtual activity levels. The attenuator set is installed against the beam port / collimator of the irradiator. |
0 - 8000X Attenuator Set Pneumatically Operated |
|
|
|
|
|
|
return to top
|
|
| PT-300 Environmental Monitor | |
|
Computer controlled systems may be configured to record information about each exposure in a database. This information includes the temperature, barometric pressure, and a correction factor to STP at the time of the exposure. This information is also recorded in the spreadsheets created during irradiator calibration. The operator may manually enter the temperature and barometric pressure, or the Environmental Monitor may be used to ensure a real-time reading of the current environmental conditions. |
|
|
|
|
|
|
|
return to top
|
|
| Electrometers and Ion Chambers | |
|
Electrometers and ionization chambers are available to precisely monitor the dose delivered during an exposure. Computer controlled systems may be configured to record this information for each exposure. Information collected by an electrometer and ionization chamber is also used to calibrate the irradiator; for computer controlled systems this calibration information also is used to configure the exposure calculator. |
Typical electrometer: Standard Imaging Max4000 |
|
|
|
|
|
| Hopewell Designs, Inc. 5940 Gateway Drive, Alpharetta, GA 30004 770-667-5770 / FAX 770-667-7539 sales@hopewelldesigns.com |
|